Product Overview
Staticmaster Rectangular Static Bar and Stand With a 7000 VRMS Static Neutralizing Supply
Condition
Used, in good condition, tested and verified functional, with minor cosmetic blemishes that do not affect performance. Sold as a set: one Staticmaster Model 6100ER Rectangular Static Bar with its cable, one I-Beam Model 6106 base and one Staticmaster Model 6010 Static Neutralizing Power Unit. Markings legible: Staticmaster, Model 6100ER, Rectangular Static Bar, Grand Island, NY, www.nrdinc.com, the NRD logo, Advanced Static Control and CE on the bar; I - BEAM, MODEL 6106, NRD, LLC, GRAND ISLAND, NY and www.nrdinc.com on the base; Staticmaster Model 6010, Input Voltage 115/230 VAC, Input Current 0.5/0.25 A, Frequency 50/60 Hz, Fuse rated 250 V, 0.5 A, Nominal Output Voltage 7000 VRMS, Max. Output Current 5 mA, High Voltage AC OUT, DANGER! High Voltage Shock Hazard, cUL US LISTED, CE and serial number C700316028 on the power unit.
Ships from our Idaho warehouse the same or next business day. We've been selling online since 1999.
Product Overview
A complete Staticmaster static neutralizing station from NRD: a rectangular static bar, an I-Beam base that stands the bar upright, and the 6010 supply that drives it. The supply runs on 115 or 230 VAC and puts out a nominal 7000 VRMS at no more than 5 mA.
Key Features
- 6010 output: nominal 7000 VRMS, 5 mA maximum
- 6010 input: 115/230 VAC, 0.5/0.25 A, 50/60 Hz
- Fuse rated 250 V, 0.5 A, in a front fuse holder
- Two High Voltage AC OUT positions at the rear, one carrying the bar cable and one under a red cap
- Front power inlet for a detachable mains cord and an orange rocker switch marked 0 and I
- Green ground lead with ring terminal on a rear stud
- Slotted mounting feet on the supply case
- 6106 I-Beam base holds the 6100ER bar upright on a bench
- 6100ER: slotted channel for two #8 sliding mounting studs
Applications
- Neutralizing static at an assembly or inspection station with the bar standing in its base
- Replacing a failed 6010 supply on an existing Staticmaster bar setup
- Adding a static bar station where a line already runs NRD equipment
Frequently Asked Questions
What mains voltage does the 6010 take?
115 or 230 VAC at 50/60 Hz, drawing 0.5 A or 0.25 A.
What fuse does it use?
A 250 V, 0.5 A fuse, replaced only with the same type and rating.
Has the set been tested?
Yes. The bar and power unit were tested and verified functional; the set is used, with minor cosmetic blemishes that do not affect performance. Flat-rate shipping in the lower 48, and orders over the free-shipping line ship free.
Seven thousand volts RMS, five milliamps at most, and all of it spent removing charge instead of making any. A high-voltage supply whose whole job is calming things down.