Product Overview
AMETEK 151071 2-Inch 1000 PSI Process Monitor with Reed Contacts
Condition
New old stock (NOS). Includes box, which is a bit rough with shelf wear as noted. Protective cap installed on lower mount fitting. Markings legible: IPS-200, CLOSES ON DECR NO, USE NO OIL, 1000 psi, AMETEK MADE IN U.S.A.
Same or next business day shipping from our Idaho warehouse. Reliable parts since 1999. Honest pricing, no nonsense.
We are here for our customers, with a no-hassle satisfaction guarantee.
Product Overview
AMETEK PMT Products IPS-200-24SG-LA (spec 151071) combines continuous mechanical pressure indication with an integrated electrical switch output in a compact 2-inch format. Rated for 0 to 1000 psi, the dial features an internal setpoint indicator configured to close contacts on decreasing pressure. Built with a stainless steel housing, an LMM male face-seal process connection, and cleaned for specialty gas or oxygen service without oil lubrication.
Key Features
- 0 to 1000 psi measurement scale
- 2.0-inch nominal dial diameter with clear analog pointer
- Magnetically actuated reed switch configured to close on decreasing pressure
- Process connection: LMM male face-seal threaded fitting with protective cap
- Prepared for specialty gas service, dial marked "USE NO OIL"
- Stainless steel case and polished front bezel
- Two-wire flying lead electrical cable
Applications
- Specialty gas cabinets monitoring bottle depletion to trigger low-pressure shutdown
- Semiconductor process gas delivery lines signaling control systems during supply pressure drops
- Laboratory manifolds where an electrical interlock protects downstream vacuum or reaction equipment
- High-pressure gas test benches requiring local readout and an automated alarm contact
Frequently Asked Questions
What is the switch actuation logic on this gauge?
The switch contacts are configured to close when system pressure falls to the setpoint, marked on the internal pointer as "CLOSES ON DECR NO".
What type of process connection does this unit use?
It features a lower mount male face-seal fitting (LMM), commonly used in high-purity gas delivery systems.
Is this gauge cleaned for oxygen service?
The dial is marked "USE NO OIL", indicating the internal wetted components were cleaned and assembled for service where hydrocarbon residue must be avoided.
How does the electrical switch connect into an alarm or interlock circuit?
The switch output routes through the integrated two-wire flying lead exiting through the rear housing grommet.
Nothing beats a dedicated dial that keeps eyes on the line while quietly standing guard over system pressure. Wire it into your interlock and let the needle do the watching.