TSI 8386A VelociCALC Plus Multi-Parameter Ventilation Meter Used

TSI

$159.97
SKU:
010425005A25
Condition:
Used
Adding to cart… The item has been added

Product Overview

TSI VelociCALC Plus 8386A Multi-Parameter Ventilation Meter with Data Logging, Articulating Probe, and Case

Condition

Used, sourced from a government research facility. Visual inspection performed; full function testing not performed. Unit powers on and displays readings - LCD active, keypad overlay intact with all function labels legible, TSI logo and model label present (Model 8386A, S/N 03090252, Rev 0). Blue housing shows light scuffs consistent with field use. The probe knuckle joint has a broken casing with exposed internal components; wire at the knuckle is intact. A handwritten label reads TEST REF / QA #403182. Comes with communication cable, gray rubber hose, brass L-tool, operation and service manual (March 2003, Rev E), and black hard-shell carry case with TSI logo. Requires four AA batteries, not included.

Carefully packed and shipped same or next business day from our Idaho warehouse. Honest equipment and straightforward service.

Online since 1999. We are here for our customers, with a no-hassle satisfaction guarantee.

Product Overview

TSI VelociCALC Plus 8386A - a handheld multi-parameter ventilation meter that measures air velocity, temperature, relative humidity, and static/differential pressure from a single articulating probe. The 8386A model automatically calculates volumetric flow rate, dew point, wet bulb temperature, and heat flow. Data logging stores up to 1,394 samples across 275 test IDs, with logged data transferable to a computer via communication cable and TSI downloading software. The articulating probe bends to reach difficult duct locations. Velocity is measured using either the integrated thermal sensor or a Pitot tube connection. Power comes from four AA batteries or an optional AC adapter.

Key Features

  • Measures air velocity (thermal sensor: 0 to 9,999 ft/min / 0 to 50 m/s), temperature, relative humidity (0 to 95% RH), and static/differential pressure (-5 to +15 in. H2O)
  • Calculates volumetric flow rate, dew point (-15°C to 49°C), wet bulb temperature (5°C to 60°C), and heat flow automatically
  • Pitot tube velocity range: 250 to 15,500 ft/min (1.27 to 78.7 m/s)
  • Temperature range (probe): -10°C to 60°C (14°F to 140°F)
  • Data logging: up to 1,394 samples and 275 test IDs
  • Articulating probe bends to access difficult duct locations
  • Converts between actual and standard velocity readings
  • Data transfer via communication cable to computer with TSI downloading software
  • Powered by four AA batteries or optional AC adapter (adapter not included)
  • Model 8386A, S/N 03090252, Rev 0 - TSI Inc., St. Paul, MN USA

Applications

  • HVAC technicians performing duct traverses and air balancing - inserting the probe into ducts or holding it at diffusers and grilles to verify airflow against design specifications and log results for commissioning reports
  • Building commissioning professionals verifying multi-parameter performance of ventilation systems in a single pass, logging velocity, temperature, pressure, and humidity simultaneously to reduce return visits
  • Industrial hygienists checking fume hood face velocity and air changes in cleanrooms, with logged data timestamped for compliance documentation and risk assessment records
  • EHS professionals measuring dew point and wet bulb temperature in occupied spaces to assess thermal stress conditions and potential for condensation-related mold growth
  • Facilities engineers troubleshooting fan performance and filter loading by measuring static pressure differentials across HVAC components, or using intermittent data logging to catch airflow problems that occur over time

Frequently Asked Questions

What is included with this unit?

Communication cable, gray rubber hose, brass L-tool, operation and service manual (March 2003, Rev E), and black hard-shell carry case with TSI logo. Four AA batteries are required and not included.

What is the condition of the probe knuckle joint?

The knuckle joint has a broken casing with exposed internal components. The wire at the knuckle is intact and readings show no problems. Wrapping the joint with tape for reinforcement is recommended before use. The probe shaft, ports, and red protective cap are present.

Is this unit calibrated?

Calibration status is not confirmed for this specific unit. Buyers requiring calibration for measurement-critical applications should factor in recalibration by a qualified service provider before deployment.

Does this unit include a Pitot tube?

A Pitot tube is not included. The unit accepts a Pitot tube connection for the high-velocity range (250 to 15,500 ft/min).

What software is needed to download logged data?

TSI downloading software is required to transfer logged data from the unit to a computer. Software is not included with this listing.

What is the difference between the 8386 and 8386A?

The 8386A has an articulating probe that bends to reach difficult areas in ductwork. The 8386 uses a straight probe. Both models perform the same measurements and calculations including dew point, wet bulb temperature, and heat flow.

This is a serious field instrument from the era when building science meant analog craft - probe in the duct, numbers on the screen, logged and documented by hand. The knuckle needs attention, but the meter is alive and the data is flowing. Tape it up, recalibrate if your application demands it, and put it back to work.

Reviews

(No reviews yet) Write a Review

The item was as described and in good and working condition.

Delivered as promised. I would order again if store has anything else I may need. THANK YOU!

Robert L.

Great seller...

fast shipping and great price for a quality tool!

Kacey S.

Just what the doctor ordered.

Good supply and price. Thxs

Ralph M.

Super Duper Fast Shipping.

Item As Described. Packaged Nicely, What A Seller.

Wayne L.

Item was as described, and very fast delivery!

5 stars across the board for every seller rating category, and I would buy from this seller again. And per my request, the capacitors were also very well packed for safe delivery.

Bruce B.

Product shipped quickly and arrived in good shape

J. Fong

Outstanding.

The instrument was well packed. It is in extremely good condition. It passed all preliminary tests.

Raymond W.

Item looks better than described, looks brand new and works great.

My old buffer was 50 years old and I sent it to buffer heaven, thanks.

Mike H.

As advertised. Would buy from again.

S. Scafer

Obtainium have been a very helpful seller to me.

In recent times I have had a few items go astray enroute to my address in Australia. This seller was most helpful & encouraging, regarding the onward tracking & eventual safe delivery of this item. This item's arrival in good condition was a joy to me as, it was a rare part that fitted my military comms. Well done seller. I would gladly recommend this seller to all potential buyers.

Jean-Pierre H.

Perfect transaction, pleasure to deal with.

M. Dante